Product information
Rack-mounted battery system (official rack name TSYS-HR140) for the AELIO+HR140 C&I energy storage system
Key features
- Customizable Battery Setup: Batteries can be flexibly configured according to customer site requirements, supporting both indoor and outdoor, as well as rack-mounted and stacked installations
- Battery Options: Two battery choices available, catering to single system capacities ranging from 100.3 kWh to 401.4 kWh
- Parallel Operation: Supports up to 10 parallel systems, meeting power requirements from 49.9 kW to 600 kW
Specifications
| Model (as printed) | TSYS-HR140; variants T-HR1003, T-HR1146, T-HR1290, T-HR1433, T-HR1576, T-HR1720, T-HR1863, T-HR2007 |
|---|---|
| Module quantity | T-HR1003 7; T-HR1146 8; T-HR1290 9; T-HR1433 10; T-HR1576 11; T-HR1720 12; T-HR1863 13; T-HR2007 14 |
| Module model | TB-HR140 |
| Module energy / rated module voltage / module capacity / battery type | 14.3 kWh / 51.2 V / 280 Ah / LiFePO4 |
| Nominal capacity [kWh] | T-HR1003 100.3 kWh; T-HR1146 114.6 kWh; T-HR1290 129.0 kWh; T-HR1433 143.3 kWh; T-HR1576 157.6 kWh; T-HR1720 172.0 kWh; T-HR1863 186.3 kWh; T-HR2007 200.7 kWh |
| Usable energy (90% DOD) | T-HR1003 90.3 kWh; T-HR1146 103.1 kWh; T-HR1290 116.1 kWh; T-HR1433 129.0 kWh; T-HR1576 141.8 kWh; T-HR1720 154.8 kWh; T-HR1863 167.7 kWh; T-HR2007 180.6 kWh |
| Nominal voltage | T-HR1003 358.4 V; T-HR1146 409.6 V; T-HR1290 460.8 V; T-HR1433 512 V; T-HR1576 563.2 V; T-HR1720 614.4 V; T-HR1863 665.6 V; T-HR2007 716.8 V |
| Operating voltage range | T-HR1003 291 ~ 408 V; T-HR1146 332 ~ 467 V; T-HR1290 374 ~ 526 V; T-HR1433 416 ~ 584 V; T-HR1576 457 ~ 642 V; T-HR1720 499 ~ 700 V; T-HR1863 540 ~ 759 V; T-HR2007 582.4 ~ 817.6 V |
| Nominal operation current | 140 (unit not printed on datasheet) |
| Maximum operation current | 140 (unit not printed on datasheet) |
| Nominal power | T-HR1003 50 kW; T-HR1146 57 kW; T-HR1290 65 kW; T-HR1433 72 kW; T-HR1576 79 kW; T-HR1720 86 kW; T-HR1863 93 kW; T-HR2007 100 kW |
| Depth of discharge | 90% |
| Cycle life (90% DOD) | 6000 |
| Charge / discharge temperature range (without heating) | 0°C to 53°C (Charge); -20°C to 53°C (Discharge) |
| Relative humidity | 0 ~ 95% (RH) |
| Altitude | <3000 m |
| Installation type | Rack Mounting |
| Environment | Indoor |
| Communication interfaces | CAN |
| Protection degree | IP20 |
| Safety | EN 62477, IEC 62619, IEC 61000-6-1/2/3/4 |
| Transport testing requirement | UN38.3 |
| Compatible inverter models (AELIO+HR140 system) | X3-AELIO-49.9K, X3-AELIO-49.9K-P, X3-AELIO-50K, X3-AELIO-60K, X3-AELIO-61K |