Product information
Hybrid inverter (single-phase, residential, battery-connected, 6 kW rated AC)
Key features
- 100 % full power backup output, delivering stable performance even at temperatures above 45 °C
- Seamless switching ≤ 4 ms
- 10 seconds of 200 % backup peak power capability
- Whole-home backup with 40 A / 63 A bypass switch
- Industry-leading Max. 20 A PV input per string
- Dual-system pressure relief structure
Specifications
| Recommended max. PV input power | 12000 Wp |
|---|---|
| Max. usable PV input power | 9600 Wp |
| Max. PV input voltage | 500 V |
| Min. PV input voltage / Startup input voltage | 40 V / 50 V |
| Rated PV input voltage | 360 V |
| MPPT operating voltage range | 40 V – 425 V |
| MPP voltage range for rated power | 230 V – 425 V |
| No. of independent MPP trackers | 2 |
| No. of PV strings per MPPT | 1 / 1 |
| Max. PV input current | 40 A (20 A / 20 A) |
| Max. DC short-circuit current | 50 A (25 A / 25 A) |
| Max. current for DC connector | 25 A |
| Battery type | Li-ion battery |
| Battery voltage range | 40 V – 60 V |
| Max. charge / discharge current | 135 A / 135 A |
| Max. charge / discharge power | 6000 W / 6000 W |
| Max. AC power from grid | 8800 W |
| Rated AC output power | 6000 W |
| Max. AC output apparent power | 6000 VA |
| Max. AC output current | 27.3 A |
| Rated AC voltage | 220 V / 230 V / 240 V |
| AC voltage range | 154 V – 276 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| Grid frequency range | 45 Hz – 55 Hz / 55 Hz – 65 Hz |
| Harmonic (THD) | < 3 % (of rated power) |
| Power factor at rated power / adjustable power factor | > 0.99 at default value at rated power / 0.8 leading to 0.8 lagging |
| Feed-in phases / connection phases | 1 / 1 |
| Max. output power for backup load (on-grid mode) | 8800 W |
| Max. output current for backup load (on-grid mode) | 40 A |
| Rated voltage (off-grid mode) | 220 V / 230 V / 240 V |
| Rated frequency (off-grid mode) | 50 Hz / 60 Hz |
| THDV (@ linear load) | < 2 % |
| Backup switch time | ≤ 4 ms |
| Rated output power (off-grid mode) | 6000 W |
| Max. output power for backup load (off-grid mode) | 6600 W |
| Peak output power | 2 times of rated power, 10 s |
| Max. efficiency / European efficiency | 97.6 % / 96.7 % |
| Degree of protection | IP65 |
| Dimensions (W * H * D) | 532 mm * 386 mm * 210 mm |
| Weight | ≤ 18 kg |
| Mounting method | Wall-mounting bracket |
| Operating ambient temperature range | -25 ℃ to 60 ℃ |
| Allowable relative humidity range | 0 % – 95 % |
| Cooling method | Natural convection |
| Max. operating altitude | 2000 m |
| Noise (typical) | < 35 dB(A) |
| Display | LCD digital touchable display & LED indicator |
| Communication | CAN, RS485, Ethernet (optional), WLAN (optional) |
| DI / DO | DI * 1 / DO * 1 |
| Arc fault circuit interrupter (AFCI) | Optional |
| Micro-inverter compatibility | Optional |
| Topology (inverter / battery BDC) | Non-isolated / Isolated |